Skip to product information
1 of 1

RAYTECH PS180 3 PHASE POWER SAFE MANAGEMENT SYSTEM UNIT

RAYTECH PS180 3 PHASE POWER SAFE MANAGEMENT SYSTEM UNIT

Protect your Expensive Audio, Lighting & Video gear with the Raytech Range of Powersafe Power Management Systems.

More Information

Sound and Lighting Rental companies, Event managers, Live Bands, DJs, AV Installers, Video Production companies etc. invest in expensive state of the art equipment for professional use. Over 60% of equipment damage is attributed to poor power conditions and generator supplies. A Single NEUTRAL failure can damage every single piece of equipment connected to the power supply within a second of the error! Over & Under voltage causes system crashes and hangs in todays digital domain. Prevent these catastrophies with POWERSAFE

Technical Specification

  • Detects & protects against following power Conditions:
  • Overvoltage
  • Undervoltage
  • Power Sags / Swells / Surges
  • Incorrect termination of 3 phase supplies (PS-180)
  • Neutral Failure
  • Under Frequency
  • Over Frequency

Monitoring :

  • Individual Phase True RMS Voltage Display
  • Individual Phase True RMS Current Display
  • Frequency Display
  • High Accuracy Measurements
  • Backlit LCD display for Setup Menu and Options
  • Earth-Neutral Voltage Monitoring. Verifies proper earthing, Neutral Displacement

Adjustable Protection Levels :

  • Over voltage 245-275 VAC
  • Under voltage 170-220 VAC with Disable
  • %-Over Frequency 50.5-55.0 hz with Disable
  • Under Frequency 45.5-49.5 hz with Disable

Features :

  • Bypass switch
  • Input Output via High current terminals / CEE norm connectos
  • Available with Distribution Options / MCB-s
View full details